Box Culvert

Box Culvert

Category: Precast

Specifications
Dry Weather Flow
With Dry Weather Flow, Without Dry Weather Flow
Nominal Size [Base (mm) x Height (mm) x Length (Meter)]
300 x 300 x 1.2m, 300 x 450 x 1.2m, 300 x 600 x 1.2m, 375 x 375 x 1.2m, 375 x 450 x 1.2m, 375 x 600 x 1.2m, 450 x 450 x 1.2m, 450 x 600 x 1.2m, 600 x 300 x 1.0m, 600 x 300 x 1.2m, 600 x 450 x 1.0m, 600 x 450 x 1.2m, 600 x 600 x 1.0m, 600 x 600 x 1.2m, 750 x 450 x 1.0m, 750 x 600 x 1.0m, 750 x 750 x 1.0m, 900 x 450 x 1.0m, 900 x 600 x 1.0m, 900 x 750 x 1.0m, 900 x 900 x 1.0m, 1200 x 600 x 1.0m, 1200 x 750 x 1.0m, 1200 x 900 x 1.0m, 1200 x 1050 x 1.0m, 1200 x 1200 x 1.0m, 1500 x 750 x 1.0m, 1500 x 900 x 1.0m, 1500 x 1050 x 1.0m, 1500 x 1200 x 1.0m, 1500 x 1350 x 1.0m, 1500 x 1500 x 1.0m, 1800 x 900 x 1.0m, 1800 x 1050 x 1.0m, 1800 x 1200 x 1.0m, 1800 x 1350 x 1.0m, 1800 x 1500 x 1.0m, 1800 x 1650 x 1.0m, 1800 x 1800 x 1.0m, 2100 x 1200 x 1.0m, 2100 x 1500 x 1.0m, 2100 x 1800 x 1.0m, 2100 x 2100 x 1.0m, 2400 x 1200 x 1.0m, 2400 x 1500 x 1.0m, 2400 x 1800 x 1.0m, 2400 x 2100 x 1.0m, 2400 x 2400 x 1.0m, 2700 x 1500 x 1.0m, 2700 x 1800 x 1.0m, 2700 x 2100 x 1.0m, 2700 x 2400 x 1.0m, 2700 x 2700 x 1.0m, 3000 x 1500 x 1.0m, 3000 x 1800 x 1.0m, 3000 x 2100 x 1.0m, 3000 x 2400 x 1.0m, 3000 x 2700 x 1.0m, 3000 x 3000 x 1.0m, 3300 x 1500 x 1.0m, 3300 x 1800 x 1.0m, 3300 x 2100 x 1.0m, 3300 x 2400 x 1.0m, 3300 x 2700 x 1.0m, 3300 x 3000 x 1.0m, 3600 x 1800 x 1.0m, 3600 x 2100 x 1.0m, 3600 x 2400 x 1.0m, 3600 x 2700 x 1.0m, 3600 x 3000 x 1.0m
Details

*As sizes can differ between brands, if the size you need isn't available in the variants, please WhatsApp us with your specific size request.*

Application :
  • Storm water drain
  • Power duct
  • Replacement of RCC hume pile at road crossing
 
Design Consideration :
 
  • The structure design of Precast RC Box Culvert is in accordance with the requirement of :
i) BS 5400 : Part 4 : 1990
ii) BD 31/01  The Design of Buried Concrete Box and Portal Frame Structures
iii) MS 1293 : Part 1 : 1992
  • Box culverts are able to withstand a standard 2m (Max.) of superimposed backfill depth and 45 units of HB vehicle live load.
  • Standard size box culverts also comply with proof load test of 112.5 kN over an area of 320mm x 320mm placed at any position on the box culvert's lid.
  • Minimum backfill depth of 600mm over box culverts are recommended to avoid undesirable direct impact load.
  • Hydrostatic pressure is eliminated by provision of weepholes placed along the centerline of the invert wall.

Types :
 
 Standard Size Box Culvert (width from 300mm to 1800mm) 
 




 Supersize Box Culvert (width from 2135mm to 3660mm) 


* B
ox culverts are available with / without dry weather flow (DWF) channels. Kindly specify your requirement.

 

View more about Box Culvert on main site