Specification
|
HSL4 Heavy Duty Wedge Anchor
|
HSL4-B Heavy Duty Wedge Anchor
|
HSL4-SK Heavy Duty Wedge Anchor
|
HSL4-G Heavy Duty Wedge Anchor
|
HSL4-G LN Heavy Duty Wedge Anchor
|
|
|

|

|

|

|

|
|
Material, corrosion
|
Carbon steel, zinc-plated
|
|
Head configuration
|
Hex head
|
Safety cap (Torque limitation nut)
|
Countersunk
|
Externally threaded
|
Externally threaded
|
|
Approvals / test reports
|
ETA, Fire, ICC-ES report (concrete), LABC, Nuclear (NQA-1), Seismic
|
ETA, Fire, ICC-ES report (concrete), LABC, Nuclear (NQA-1), Seismic
|
ETA, Fire, ICC-ES report (concrete), LABC, Nuclear (NQA-1), Seismic
|
ETA, Fatigue, Fire, ICC-ES report (concrete), LABC, Nuclear (NQA-1), Seismic
|
ETA, Fatigue, Fire, ICC-ES report (concrete), LABC, Nuclear (NQA-1), Seismic
|
|
Base materials
|
Concrete (cracked), Concrete (uncracked)
|
|
PROFIS software
|
Yes
|
|
Applications
|
-
Heavy-duty fastenings in high safety-relevant or dynamic applications, including applications in nuclear power plants
-
Anchoring where extensive approval back-up or technical back-up is required, e.g. machines, heavy equipment, steel columns, heavy pipe supports, pumps, beam supports, medical equipment, cantilevers, cranes, car hoists, etc.
|
-
Heavy-duty fastenings in highly safety-relevant or dynamic applications, including applications in nuclear power plants
-
Applications where extensive approval back-up or technical back-up is required, e.g. machines, heavy equipment, steel columns, heavy pipe supports, pumps, beam supports, medical equipment, cantilevers, cranes, car hoists, etc.
|
-
Fastenings in safety-relevant and/or dynamic applications where a flush installation or aesthetic appearance is required, including applications in nuclear power plants
-
Applications where extensive approval back-up or technical back-up is required
-
Examples are medical equipment, hand rails, machines, car hoists, safety fences, pumps, etc.
-
Applications requiring an aesthetic countersunk head finish
|
-
Heavy-duty fastenings in highly safety-relevant or dynamic applications, including applications in nuclear power plants
-
Applications where extensive approval back-up or technical back-up is required, e.g. machines, heavy equipment, steel columns, heavy pipe supports, pumps, beam supports, medical equipment, cantilevers, cranes, car hoists, etc.
|
-
Heavy-duty fastenings in highly safety-relevant or dynamic applications, including applications in nuclear power plants
-
Applications where extensive approval back-up or technical back-up is required, e.g. machines, heavy equipment, steel columns, heavy pipe supports, pumps, beam supports, medical equipment, cantilevers, cranes, car hoists, etc.
|
|
Advantages
|
-
High tension and shear load capacities
-
Force-controlled expansion which allows follow-up expansion
-
ETA Option 1 for cracked and uncracked concrete
-
ICC-ES/AC 193 for cracked or uncracked concrete and seismic applications
-
Suitable for dynamic loading including fatigue, seismic and shock
|
-
High tensile and shear load capacity
-
Force-controlled expansion which allows follow-up expansion
-
Special safety cap helps ensure proper installation torque is applied even if not using a calibrated torque wrench
-
ETA Option 1 for cracked and uncracked concrete
-
ICC-ES/AC 193 for cracked or uncracked concrete and seismic applications
|
-
Aesthetic appearance and no tripping hazard due to flush installation
-
High tensile and shear load capacity, force-controlled expansion allows follow-up expansion
-
ETA Option 1 for cracked and uncracked concrete
-
ICC-ES/AC 193 for cracked and uncracked concrete and seismic
-
Suitable for dynamic loading including fatigue, seismic and shock
|
-
High tensile and shear load capacity
-
Force-controlled expansion allows follow-up expansion
-
ETA Option 1 for cracked and uncracked concrete
-
ICC-ES/AC 193 for cracked or uncracked concrete and seismic applications
-
Suitable for dynamic loading including fatigue, seismic and shock
|
-
High tensile and shear load capacity
-
Force-controlled expansion allows follow-up expansion
-
ETA Option 1 for cracked and uncracked concrete
-
ICC-ES/AC 193 for cracked and uncracked concrete and seismic
-
Suitable for dynamic loading including fatigue, seismic and shock
|